Specifications

Features

References

Assortment

Accessories

Product configurator

COLIBRI Flood

Product Overview

Solve all your budgeting challenges with the unprecedented value of the Colibri street luminaires. Featuring an IP66 rating, vandal protection, robust aluminium body, brightness up to 6028 lm, and many hardware customization options, Colibri can be the missing link in urban projects of any scale. With the best price-performance ratio on the market. There are two spigot options: post-top and side-entry. You can also choose between the regular and the floodlight models – all versions come with full ENEC/ENEC+/Class I/Class II certification. Further customization includes different drivers, optics, sockets (Zhaga/NEMA), reflectors, and connectors. Colibri – wholesale pricing, luxurious design.

Basic colours

  • Silver RAL9006
  • Asphalt DB703
  • Black RAL9005
  • RAL7035

Specification

V

220 - 240 / 110 - 277 1

Hz

50 - 60

W

5 - 45

lm

452 - 6028 2

lm/W

91 - 146

K

2700 / 3000 / 4000 3

-40 to +50 | up to 35 W
-40 to +35 | 35 - 45 W

CRI

>70 / >80 / >90 3

mm

355 x 197 x 67

Body: Die-cast aluminium

Dimming: DALI / 1 - 10 V / Midnight dimming /
Step dimming / Mains dimming

Initial chromaticity: MacAdam 5

Lifetime: Eco 100 000 h (L90B10) at Ta = 25 °C* /

Standard / High density 100 000 h (L98B10) at Ta = 25 °C*

Warranty: 5 years

Installation: Pre-wired cable 30 cm 4

Mounting: On bracket / wall / ceiling

Socket: NEMA / Top and Bottom Zhaga

Intelligent control: Stand-alone / Group / CMS

Sensor: Motion / Motion + Daylight / Daylight

Surge protection: 4 / 6 / 10 kV 5

Corrosion protection: Up to C5

Neto weight: Up to 2.9 kg

Max. wind load area, SCd, m2: 0,020

Class I
Class II
IP66
IK08
IK09 6
CE
UKCA
RoHS
cUL 7
Zhaga zdi4
ENEC
ENEC Plus
Synergrid approved 7
International EPD System
LED module replaceable by a professional
LED driver replaceable by a professional

1 Maximum operating voltage, ENEC certificate voltage 220 - 240 V, UL certificate voltage 110 - 277 V
2 Lumen output indicated at CRI > 70
3 1800 / 2200 / 3500 / 5000 / 5700 / 6500 K available on request along with other not listed CRI and CCT
4 Other lengths available on request
5 10 kV (L-N; L/N-PE) surge protection device available on request
6 With clear glass
7 Coming soon

*This value is only informative and may change according to selected article. LED Lifetime is strongly depending from LEDs current and junction temperature – increase in LED current and luminaire power lead to increase of junction temperature and as consequence lifetime decrease. Thus, luminaire models with lower power, lower current (and lower junction temperature) will have higher lifetime than standard models. And high power and high current luminaire models may have negative lifetime deviation comparing to standard models. To receive precise value please contact VIZULO export representatives.

Technical parameters for final product can differ from typical data by 7% due to special conditions of LED manufacturing processes

Download Documents

Features

Electronics

Controls & Connectivity

Light

Optics

Best selling articles

Other options available on request

Optic
Affects light distribution. Other optics available on request. Press on "Explore all optics" above to see the available options.
Explore all optics
L05
L08
L35
V05
V35
Flux (lm)
1099
5375
1099
5375
Efficacy (lm/W)
96
131
96.4
131.4
Power (W)
10
45
10
45
CCT (K)
CCT Lower value = Warmer light Higher value = Cooler light Contact our sales representative to request other values.
  • 3000
  • 4000
Dimming
Control interface: • DALI - Industry standard for digital control of luminaires. • Midnight dimming - Automatically adjusts output level based on preprogrammed schedule. • D4i - Comes equipped with Zhaga socket for external connection of sensors and controllers. By default the socket is mounted on top (other configurations available on request).
  • Midnight dimming
  • Midnight dimming + DALI
  • D4i (Zhaga)
Surge protection
Protects against voltage surges. Comes either integrated in driver or as a separate built-in device - SPD. The latter offers higher protection level than the former. Typical values: • Driver: L/N-PE - 10 kV; L-N - 6 kV • SPD: L/N-PE - 10 kV; L-N - 10 kV
  • 6 ... 10 kV
  • SPD 10 kV
Insulation
Class I - Requires connection to electrical earth Class II - Double insulated (no earth connection required)
  • Class I
  • Class II
LED type
Standard (outdoor) - Premium LED's (L98 at 100 000 h) Eco - Economic LED's (L90 at 100 000 h)
  • Flood
  • Flood, Eco
Optic Model Flux lm Efficacy lm/W Power W CRI CCT K Dimming LED type Datasheet LDT file
CLF 010 730 L05 A008 CJF MG183101275 1215 121.5 10 70 3000 Midnight dimming Flood
CLF 010 730 L05 A008 CJF MG283101276 1215 121.5 10 70 3000 Midnight dimming Flood
CLF 010 730 L05 A008 CJF MH183101277 1215 121.5 10 70 3000 Midnight dimming Flood
CLF 010 730 L05 A008 CJF MH283101278 1215 121.5 10 70 3000 Midnight dimming Flood
CLF 010 730 L05 A008 CJF RG183101279 1215 121.5 10 70 3000 Midnight dimming + DALI Flood
CLF 010 730 L05 A008 CJF RG283101280 1215 121.5 10 70 3000 Midnight dimming + DALI Flood
CLF 010 730 L05 A008 CJF RH183101281 1215 121.5 10 70 3000 Midnight dimming + DALI Flood
CLF 010 730 L05 A008 CJF RH283101282 1215 121.5 10 70 3000 Midnight dimming + DALI Flood
CLF 010 730 L05 A008 CJF ZG183101283 1194 119.4 10 70 3000 D4i (Zhaga) Flood
CLF 010 730 L05 A008 CJF ZG283101284 1194 119.4 10 70 3000 D4i (Zhaga) Flood

Optical

Mounting

Controllers and sensors for smart systems

Terminal blocks and plugs

Cables

Sockets and caps for smart systems

LED drivers

en